Detection Systems DS7060 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Systemy kontroli dostępu bezpieczeństwa Detection Systems DS7060. DS 7060 - Theft Prevention Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
4/98
Detection Systems PTY Ltd.
Unit 21, 45 Gilby Road
Mount Waverley 3149, Australia
61 3 9558 8088
Fax: 61 3 9588 8089
Detection Systems PTY Ltd.
Unit 2, The Riverside Centre
148 James Ruse Drive
Parramatta, NSW 2150, Australia
61 2 891 4944 Fax: 61 2 891 5844
Detection Systems, Inc., 130 Perinton Parkway, Fairport, New York, USA 14450-9199
Copyright 1997-98 Detection Systems, Inc. (716) 223-4060 (800) 289-0096 Fax: (716) 223-9180 DS7060-AUS Reference Guide P/N 36624C
Reference Guide
for the
DS7060 Control/Communicator
Keypad Quick Reference Guide
Turning On (arming) your System
Normal Arming PIN + [On]
Perimeter Arming, no entry delay PIN + [No Entry] [Perimeter Only]
Perimeter Arming, with entry delay PIN + [Perimeter Only]
Maximum Security Arming PIN + [No Entry] [On]
Force Arming PIN + Arming Sequence + [Bypass]
Zone Bypass PIN + [Bypass] followed by the Zone number
Custom Arm PIN + [#] + [4]
Quick Arm [#] + [On]
Turning Off (disarming) your System
PIN + [Off]
Commands for other System Features
Chime Mode PIN + [#] [7]
Zone Test PIN + [#] [8] [1]
Read Alarm History PIN + [#] [8] [9]
Battery Test PIN + [System Reset]
Communicator Test PIN + [#] [8] [2]
Fire Reset PIN + [System Reset]
Fire Trouble PIN + [Off] to silence, PIN + [System Reset] to clear
Remote Program Dial Out PIN + [#] [8] [3]
Remote Program Answer PIN + [#] [8] [6]
Local Battery/Sounder Test PIN + [#] [8] [5]
Error Display PIN + [#] [8] [7]
Error Display Reset PIN + [System Reset]
Clear Zone Bypass PIN + [Bypass] [*] to clear
Guest Code Enable PIN + [#] [8] [4]
NOTE: Examples are shown in Commercial Mode, but are valid for any mode.
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - DS7060 Control/Communicator

4/98Detection Systems PTY Ltd.Unit 21, 45 Gilby RoadMount Waverley 3149, Australia61 3 9558 8088Fax: 61 3 9588 8089Detection Systems PTY Ltd.Unit 2, T

Strona 2 - 63(&,),&$7,216

4/98Page 10 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide• Intrusion: This is an output programmed to latchwith any Burg zo

Strona 3

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 11• Duress Code: If this option is selected and Code14 is used to di

Strona 4

4/98Page 12 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide• Easy Exit: If the system is armed and there havebeen no zones vi

Strona 5 - 2SHUDWLQJ*XLGH

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 13• Disabled: Special Key not programmed.• Invisible: Special Key

Strona 6

4/98Page 14 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide• Dial Pulse: If programmed, the panel will dial tophone number 1,

Strona 7

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 15Program locations 24 through 36 are used differentlyfor the particul

Strona 8

4/98Page 16 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide• Zone Trouble: This report is sent when a zonetrouble condition o

Strona 9

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 17• Open: This report is sent when the system hasbeen disarmed. In C

Strona 10

4/98Page 18 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide• System Trouble: This report is sent when acontrol trouble condit

Strona 11

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 19NOTE: If the account code is “0000” no reports willbe sent.NOTE: If

Strona 12

4/98Page 2 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide6<67(029(59,(:The DS7060 Control/Communicator is a fullyinte

Strona 13

4/98Page 20 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference GuideSee the Users Guide for more information onPersonal Identification N

Strona 14

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 21History Controls determine what events arestored in the panels histo

Strona 15

4/98Page 22 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference GuideCustom Chime determines which zones will chimein the chime mode. Onl

Strona 16

Page 23 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference GuidePIN NUMBER NAMEExample 1038 Thomas J. BrownUser 01User 02User 03User 04U

Strona 17

Detection Systems (Aust) Pty LtdDS7060 Reference Guide P/N 36624B

Strona 18

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 3(1&/2685(,167$//$7,21The DS7060 control/communicator and th

Strona 19

4/98Page 4 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide&21752/7(50,1$/:,5,1*WARNING: Before servicing this equipm

Strona 20

4/98Page 5 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide2SHUDWLQJ*XLGH• The DS7443 is a 6 zone LED keypad; its LEDs re

Strona 21

4/98Page 6 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide3URJUDPPLQJWKH'6A zone is an input to the DS7060 Cont

Strona 22

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 7armed, these zones are delayed if a delayed zoneis violated first, or

Strona 23 - Example 1038 Thomas J. Brown

4/98Page 8 Copyright  1997-98 Detection Systems, Inc. DS7060-AUS Reference GuideThis determines whether the user can bypass thezone. Zones programmed

Strona 24

4/98DS7060-AUS Reference Guide Copyright  1997-98 Detection Systems, Inc. Page 9All six zones can be programmed to respond at either300 ms (±100 ms)

Komentarze do niniejszej Instrukcji

Brak uwag